Published October 1986 | Version v1
Journal article

Radiographic testing of prestressed concrete structures

Creators

  • 1. Vysoke Uceni Technicke, Brno (Czechoslovakia)

Description

The roof structure was tested of a textile manufacturing hall consisting of 11 trusses of prestressed concrete of the SPPG-18 type with a span of 18 m. The axial distance of the girders was three metres. The distribution was studied of the prestressed reinforcement of the trusses and the level of the filling of ducts with injected mortar. A 60Co source with an activity of 1.1322 TBq (29.1 Ci) was used for radiographic inspection. The radiograms were made on Agfa-Gevaert D 7+Pb films and an MD-100 microdensitometer was used for evaluation. The testing showed that of the total number of 24 checked ducts only seven had been properly injected, 14 had been incompletely injected and in three cases the quality of injecting could not be assessed. A highly irregular distribution of cables was found. Next to the radiographic check a phenolphthalein test was made to detect the level of carbonized concrete. Also checked was the strength of the concrete. (E.S.)

Additional details

Additional titles

Original title (Czech)
Radiograficka kontrola konstrukci z predpjateho betonu

Publishing Information

Journal Title
Inz. Stavby
Journal Volume
34
Journal Issue
10
Series
Inz. Stavby.
Journal Page Range
525-529
ISSN
0021-0277
CODEN
IZYSA