Published 2007 | Version v1
Miscellaneous

Thermoluminescent response of LiF: Mg, Cu, P (GR-200) below an electron beam of 6 MeV

  • 1. Universidad Autonoma Metropolitana-lztapalapa, Av. San Rafael Atlixco 87. Col. Vicentina, 09340 Mexico D.F. (Mexico)
  • 2. Hospital General de Mexico, Balmis 148, 06726 Mexico D.F. (Mexico)
  • 3. Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Unidad Legaria del IPN, Av. Legaria 694, Col. Irrigacion, 11500 Mexico D.F. (Mexico)

Description

Full text: In this work the experimental results of studying the thermoluminescent response (TL) of LiF:Mg,Cu,P (GR-200) previously irradiated with 6 MeV electrons are presented. The electrons beam was generated by a Lineal Accelerator VARIAN I for medical use. The lineal accelerator is installed in the General Hospital of Mexico (HGM). A lot of 25 thermoluminescent dosemeters (DTL) was used. The mass and volume of each one of them were determined. Obtaining a variation of 14% in standard deviation (SD). The DTLs were irradiated to an energy of 6 MeV. The dose given to the DTL was of 50 c Gy. The linearity of the response of the GR-200 also was determined. (Author)

Availability note (English)

Available in abstract form only; full text entered in this record

Additional details

Additional titles

Original title (Spanish)
Respuesta termoluminiscente de LiF: Mg, Cu, P (GR-200) ante un haz de electrones de 6 MeV

Publishing Information

Imprint Pagination
1 p.
Report number
INIS-MX--2387

Conference

Title
10. International Symposium. 20 National Congress on Solid State Dosimetry
Dates
24-27 Sep 2007
Place
Puebla (Mexico)