Published December 1997 | Version v1
Report

Analysis of break of the steam line from SG 1, 2, 3, 4, 5, and 6, segment beyond the hermetic zone, at the Dukovany-1 reactor unit 1

Description

The calculation was performed based on the US NRC Standard Review Plan, Sections 3.6.1 and 3.6.2, and the break points were predicted. The calculation gave evidence that these are only the welds with the hermetic penetration. (P.A.)

Availability note (English)

Available from Nuclear Research Institute Rez, 250 68 Rez, Czech Republic

Additional details

Additional titles

Original title (Czech)
Analyza na roztrzeni potrubi pary z PG 1, 2, 3, 4, 5 a 6 - cast vne hermeticke zony EDU, blok 1

Publishing Information

Imprint Pagination
81 p.
Report number
UJV--11031-T

Optional Information

Notes
2 tabs., 42 figs., 8 refs.