An approach to dose calculation for single linear brachytherapy source capsule

  • 1. Virginia Univ., Charlottesville (USA). Div. of Radiological Physics
  • 2. Rush-Presbyterian-St. Luke's Medical Center, Chicago, IL (USA). Dept. of Therapeutic Radiology

Description

A dose computation model that considers a brachytherapy sealed line source as a cylindrical volume of radioactive material contained within a cylindrical metallic shell has been developed. This three-dimensional model takes into account the attenuation within the radioactive source in greatest detail. The relative dose estimates obtained by this model are discussed for two typical brachytherapy sources. (orig.)

Abstract (German)

Ein Modell zur Dosisberechnung wird entwickelt, das eine zur Kontakttherapie benutzte, umschlossene stabfoermige Quelle als zylindrisches Volumen aus radioaktivem Material betrachtet, das von einer zylindrischen Metallhuelle umgeben ist. Dieses dreidimensionale Modell beruecksichtigt in allen Einzelheiten die Abschwaechung innerhalb der radioaktiven Quelle. Die mit einem solchen Modell erhaltenen Ergebnisse fuer die relative Dosis werden anhand von zwei typischen, in der Kontakttherapie verwendeten Quellen diskutiert. (orig.)

Additional details

Publishing Information

Journal Title
Strahlentherapie
Journal Volume
158
Journal Issue
2
Series
Strahlentherapie.
Journal Page Range
107-111
ISSN
0039-2073

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
13692476
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
COMPARATIVE EVALUATIONS; DOSIMETRY; IMAGES; IRRADIATION CAPSULES; ISODOSE CURVES; MATHEMATICAL MODELS; PLANNING; RADIATION SOURCE IMPLANTS; RADIOTHERAPY
Descriptors DEC
IMPLANTS; MEDICINE; RADIATION SOURCES; THERAPY