Investigation of the biodistribution and calculation of dosimetry of Ga-68-DOTATOC-for patients imaged in the routine clinical setting for diagnosis or exclusion of neuroendocrine tumours. Patients methods: Dynamic PET/CT-imaging (Biograph 16) was performed over 20 min in 14 patients (8 men, 6 women) after injection of (112 ± 22) MBq 68Ga-DOTATOC followed by whole body 3D-acquisition (8 bed positions, 3 or 4 min each) 30 min p.i. and 120 min p.i., Urinary tracer elimination was measured and blood activity was derived non-invasively from the blood pool of the heart. The relevant organs for dosimetry were spleen, kidneys, liver, adrenals, urinary bladder and pituitary gland. Dosimetry was performed using OLINDA/EXM 1.0 software and specific organ uptake was expressed as standardized uptake values (SUVs). Results Rapid physiological uptake of the radiotracer could be demonstrated in liver, spleen and kidneys, adrenals and pituitary gland (mean SUVs were 6, 20, 16, 10, and 4, respectively). Radiotracer elimination was exclusively via urine (16% of injected dose within 2h); no redistribution could be observed. The spleen and the kidneys received the highest radiation exposure (0.24 mSv/MBq, 0.22 mSv/MBq resp.), mean effective dose yielded 0.023 mSv/MBq. Conclusion: 68Ga-DOTATOC is used extensively for diagnosis of somatostatin receptor positive tumours because it has several advantages over the 111In-labelled ligand. The derived dosimetric values are lower than first approximations from the biological data of OctreoScan. The use of CT for transmission correction of the PET data delivers radiation exposure up to 1 mSv (low dose). (orig.)
Additional details
Publishing Information
- Journal Title
- Nuklearmedizin
- Journal Volume
- 48
- Journal Issue
- 5
- Journal Page Range
- p. 201-207
- ISSN
- 0029-5566
- CODEN
- NUKLDV
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 41000141
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ADRENAL GLANDS; BLADDER; CARCINOMAS; COMPUTERIZED TOMOGRAPHY; ENDOCRINE GLANDS; GALLIUM 68; KIDNEYS; LIVER; PATIENTS; POSITRON COMPUTED TOMOGRAPHY; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSES; RADIOPHARMACEUTICALS; TRACER TECHNIQUES
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-PLUS DECAY RADIOISOTOPES; BODY; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; DISEASES; DOSES; DRUGS; ELECTRON CAPTURE RADIOISOTOPES; EMISSION COMPUTED TOMOGRAPHY; ENDOCRINE GLANDS; GALLIUM ISOTOPES; GLANDS; HOURS LIVING RADIOISOTOPES; INTERMEDIATE MASS NUCLEI; ISOTOPE APPLICATIONS; ISOTOPES; LABELLED COMPOUNDS; MATERIALS; NEOPLASMS; NUCLEI; ODD-ODD NUCLEI; ORGANS; RADIOACTIVE MATERIALS; RADIOISOTOPES; TOMOGRAPHY; URINARY TRACT