Beam current dependence of the equilibrium temperature with a laser cooling
Creators
- 1. Kyoto Univ., Inst. for Chemical Research, Uji, Kyoto (Japan)
- 2. Kyoto Univ., Inst. of Advanced Energy, Uji, Kyoto (Japan)
- 3. Hiroshima Univ., Graduate School of Advanced Sciences of Matter, Higashi-Hiroshima, Hiroshima (Japan)
- 4. Tsinghua Univ., Beijing (china)
Description
Particle number dependence of hirizontal temperatures are measured at Small Laser-equipped Storage Ring (S-LSR) at Kyoto University. With a resonant coupling condition of tunes (νx, νy, νs) = (2:068; 1:105; 0:068), horizontal temperature decreases with power of 0.3 of particle numbers. The coupling constant of horizontal and longitudinal temperature: Ch = Th/T∥ is 0.12 with the coupling condition, which is larger than that with non-coupling conditions; 0.02. This indicates a strong coupling occurred with an synchro-betatron resonant coupling condition. (author)
Additional details
Identifiers
Publishing Information
- Imprint Title
- Proceedings of the 8th annual meeting of Particle Accelerator Society of Japan
- Imprint Pagination
- [1377 p.]
- Journal Page Range
- [3 p.]
Conference
- Title
- 8. annual meeting of Particle Accelerator Society of Japan
- Dates
- 1-3 Aug 2011
- Place
- Tsukuba, Ibaraki (Japan)
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 45043391
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- BEAM COOLING; BEAM CURRENTS; CRYSTALLIZATION; EDUCATIONAL FACILITIES; JAPANESE ORGANIZATIONS; LASERS; MAGNESIUM 24 BEAMS; PERFORMANCE TESTING; STORAGE RINGS; THERMAL EQUILIBRIUM
- Descriptors DEC
- BEAMS; CURRENTS; EQUILIBRIUM; ION BEAMS; NATIONAL ORGANIZATIONS; PHASE TRANSFORMATIONS; TESTING
Optional Information
- Notes
- 8 refs., 6 figs., 1 tab.