Published 1991 | Version v1
Report Open

Results of lasing linewidth narrowing on VEPP-3 storage ring optical klystron

Description

In order to decrease the linewidth optical cavity on VEPP-3 storage ring optical klystron was up-dated. A glass plate with parallel planes as natural interferometer was used. With the 1.2 mm thick glass plate installed inside the optical cavity lasing with a very narrow linewidth have been reached. The minimum relative lasing linewidth, 2.7x10-6 (λ=6250A, Δλ=0.017A) was 30 time narrower than the minimum one without the plate (Δλ=0.6A). The average power was the same in both cases. 6 refs.; 6 figs

Availability note (English)

MF available from INIS under the Report Number.

Files

23031709.pdf

Files (326.7 kB)

Name Size Download all
md5:c4c3b5b9fa242e653f0da12b4b32270e
326.7 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
17 p.
Report number
IYaF--91-4