Construction of dose response curves up to 6 Gy for Micronucleus and Dicentric Chromosome Aberration Assay with 6 MV X-ray Beam
- 1. Radiation Dosimetry Laboratory, Department of Medical Physics, Bharathiar University, Coimbatore 641 046, Tamil Nadu (India)
- 2. Plant Genetic Engineering Laboratory, Department of Biotechnology, Bharathiar University, Coimbatore 641 046, Tamil Nadu (India)
- 3. Department of Medical Physics, Bharathidasan University, Trichirapalli 620 024, Tamil Nadu (India)
Description
Highlights: • Large scale bio-dosimetry is enforced for the advent LINAC usage emergency concern. • Calibration curves were plotted by CBMN and DCA assays for 6 MV X-ray beam with the dose rate of 300 cGy/min. • Compared manually constructed curves with CABAS and Dose estimation programs. • Linear (α) and Quadratic () co-efficient variation was found between up to 4 Gy and 6 Gy constructed graph. • Accuracy of the dose estimation was verified for constructed calibration curves. In-vitro dose response curves were built with 6 MV X-ray for a dose range of 0.1–6 Gy, at a dose rate of 300 cGy/min, using Linear Accelerator (LINAC, SIMENS PRIMUS) for Cytokinesis-Block Micronucleus (CBMN) and Dicentric Chromosome Aberration assay (DCA). The dose response curves constructed up to 6 Gy and also up to 4 Gy using the manual method were compared to those curves obtained with the software program such as CABAS (V.2) and Dose Estimate software (V.5.2). The alpha and beta coefficients for MN and CA obtained for the curves constructed up to 6 Gy showed variation compared to those obtained in dose response curve constructed up to 4 Gy. However, the doses estimated based on these coefficients did not show much variation. The results are discussed in this paper.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.radmeas.2018.05.012Additional details
Identifiers
- DOI
- 10.1016/j.radmeas.2018.05.012;
- PII
- S1350448718300623;
Publishing Information
- Journal Title
- Radiation Measurements
- Journal Volume
- 115
- Journal Page Range
- p. 60-68
- ISSN
- 1350-4487
- CODEN
- RMEAEP
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 54105380
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- ACCURACY; CALIBRATION; CHROMOSOMAL ABERRATIONS; COMPUTER CODES; DICENTRIC CHROMOSOMES; DOSE RATES; DOSIMETRY; GRAPH THEORY; IN VITRO; LINEAR ACCELERATORS; MANUALS; RADIATION ACCIDENTS; X RADIATION
- Descriptors DEC
- ACCELERATORS; ACCIDENTS; CHROMOSOMES; DOCUMENT TYPES; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MATHEMATICS; MUTATIONS; RADIATIONS
Optional Information
- Copyright
- Copyright (c) 2018 Elsevier Ltd. All rights reserved.