Published November 1983
| Version v1
Journal article
Electrodecontamination of glove-box materials
Description
A basic electrolyte planned for use as an electrodecontamination step in the Advanced Size Reduction Facility is evaluated. The effects of process variables on metal dissolution rates are investigated, and optimum process conditions are identified. Decontamination to low-level waste standards is achieved through the removal of 2.4 mg/cm2 metal surface. The fastest throughput rates are achieved with solutions of pH 7, low temperatures (350C), and with low-chromium levels in the electrolyte. Electrical efficiencies of the process range from 10 to 20%
Additional details
Publishing Information
- Journal Title
- Nucl. Technol.
- Journal Volume
- 63
- Journal Issue
- 2
- Series
- Nucl. Technol.
- Journal Page Range
- 271-285
- ISSN
- 0029-5450
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 16011265
- Subject category
- S12: MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES;
- Descriptors DEI
- CHROMIUM; DECONTAMINATION; DISSOLUTION; EFFICIENCY; ELECTROLYSIS; ELECTROLYTES; ENERGY CONSUMPTION; ENERGY CONVERSION; GLOVEBOXES; LOW-LEVEL RADIOACTIVE WASTES; MEDIUM TEMPERATURE; METALS; OPTIMIZATION; PERFORMANCE; PH VALUE; QUANTITY RATIO; SOLUTIONS
- Descriptors DEC
- CLEANING; CONVERSION; DISPERSIONS; ELEMENTS; EQUIPMENT; HOMOGENEOUS MIXTURES; LABORATORY EQUIPMENT; MATERIALS; MIXTURES; RADIOACTIVE MATERIALS; RADIOACTIVE WASTES; TRANSITION ELEMENTS; WASTES