Program controlled system for measuring and monitoring the electron coherent radiation spectrum of Yerevan synchrotron

Description

An automatic system for measurement, processing and control of energy spectrum of polarized photons realized at the Yerevan electron synchrotron is described. For measuring energy spectra of intensive high energy photon beams a pair spectrometer is used which comprises an aluminium target-converter, an analizing magnet and 2 telescopes of scintillation counters for electron-positron pairs registration. the procedure of spectra measurement by the pair spectrometer is reduced to determining the converted e+e- pairs yield at certain values of the H field intensity of the analizing magnet. An algorithm of the data express-processing for operative monitoring of peak energy stability of electron coherent radiation spectrum is given. The spectra measurement results obtained under real experimental conditions are presented

Availability note (English)

MF available from INIS under the Report Number.

Files

13645733.pdf

Files (430.7 kB)

Name Size Download all
md5:0fb781152aeeb07fefbc457fd2d816b1
430.7 kB Preview Download

System files (24.5 kB)

Name Size Download all

Additional details

Additional titles

Original title (Russian)
Программно управляемая система измерения и контроля спектра когерентного излучения электронов Ереванского синхротрона

Publishing Information

Imprint Pagination
16 p.
Report number
EFI--398(5)-80

Optional Information

Notes
6 refs.; 6 figs.