Published January 9, 1993 | Version v1
Journal article

Plasma-sprayed coatings for titanium alloy oxidation protection

  • 1. General Electric Corporate Research and Development, Schenectady, NY (United States)

Description

The behavior of several different types of plasma-sprayed coatings applied to typical α + β titanium alloys was studied in air at elevated temperatures. Ductile coatings of MCr and MCrAlY type were found to confer protection against oxidation and embrittlement for hundreds of hours during rapid thermal cycling in flowing air to at least 850degC. Measurements of the extent of interdiffusion of elements across the coating-alloy interface as functions of time and temperature were made. Typically, cobalt and iron from a coating may penetrate to depths of a few tens of micrometers into the alloy substrate after 1000 h exposure at 850degC. (orig.)

Part of:
The effect of annealing unimplanted and krypton implanted uranium dioxide using positrons

Additional details

Publishing Information

Journal Title
Surface and Coatings Technology
Journal Volume
56
Journal Issue
2
Journal Page Range
p. 109-117.
ISSN
0257-8972
CODEN
SCTEEJ

Optional Information