Published November 1978 | Version v1
Journal article

Analysis of uranium ores by energy dispersive X-ray fluorescence

  • 1. Technische Hochschule Darmstadt (Germany, F.R.). Fachbereich Anorganische Chemie und Kernchemie

Description

The determination of uranium in ores by energy-dispersive X-ray fluorescence (XFA) is demonstrated for uranium ore samples of known content. For calibration silica gel standards are used. Matrix effects are corrected by measuring the Compton scattering peaks. The radionuclide 109Cd as well as a X-ray tube in combination with Mo or Sn as secondary targets are suited as X-ray sources. The mean relative deviation of the values found from the given values is 5%. (orig.)

Abstract (German)

Die Anwendbarkeit der energiedispersen Roentgenfluorescenzanalyse zur Bestimmung des Urangehaltes in Erzen wird am Beispiel von Uranerzproben bekannten Gehaltes demonstriert. Fuer die Eichung werden Kieselgel-Standards verwendet. Die Matrixeffekte werden mit Hilfe der Compton-Streupeaks korrigiert. Als Roentgenquellen eignen sich sowohl eine 109Cd-Radionuklidquelle als auch eine Roentgenroehre mit Mo und Sn als Sekundaertarget. Die mittlere relative Abweichung der Analysenwerte von den gegebenen Werten betraegt 5%. (orig.)

Additional details

Additional titles

Original title (German)
Analyse von Uranerzen mit Hilfe der energiedispersiven Roentgenfluorescenz

Publishing Information

Journal Title
Z. Anal. Chem.
Journal Volume
293
Journal Issue
2
Series
Z. Anal. Chem.
Journal Page Range
107-109