Published 1990 | Version v1
Journal article

Potential use of the UVVVR personnel neutron dosemeter in the neutron fields of nuclear power plants

  • 1. Institut Hygieny a Epidemiologie, Prague (Czechoslovakia). Ustav Hygieny Zareni
  • 2. Ustav pro Vyzkum, Vyrobu a Vyuziti Radioisotopu, Prague (Czechoslovakia)

Description

With regard to the expected requirement of neutron monitoring with a personnel dosemeter for a selected group of the nuclear power plant staff, a method of determination of dose equivalent H in these fields, based on a track detector, has been developed in UVVVR. For the region of high H values it works as a combined albedo- and fast-neutron dosemeter. In the region of low H values the calibration of the dosemeter is based on the assumption of the representative characterization of the neutron energy distributions in the nuclear power plants. The proposed method is analyzed in detail and a sufficient precision and sensitivity of the system is demonstrated (with the detectability treshold of H∼60 μSv). (author). 3 figs., 1 tab., 8 refs

Additional details

Additional titles

Original title (Czech)
Moznosti vyuziti osobniho dozimetru neutronu UVVVR v neutronovych polich jadernych elektraren

Publishing Information

Journal Title
Radioisotopy
Journal Volume
31
Journal Issue
1
Series
Radioisotopy.
Journal Page Range
14-23
ISSN
0322-8657
CODEN
RAISB

Optional Information

Notes
English translation available from Nuclear Information Center, 156 16 Prague 5-Zbraslav, Czechoslovakia, at US$ 10 per typewritten page.