The ECR ion source, beam line from ECR to SFC and electrostatic inflector have been designed and installed to increase ion species and beam intensity. The working points are mainly located in the third harmonic accelerating region. The central region was studied carefully, and the Dee and dummy Dee were rebuilt to match the external injection system. Other improvements were adopted to improve the performance and operation efficiency of SFC. The commissioning of the upgraded SFC is also described

Additional details

Publishing Information

Publisher
Atomic Energy Press
Imprint Place
Beijing (China)
ISBN
7-5022-1181-0
Imprint Title
Proceedings of heavy ion research facility in Lanzhou
Imprint Pagination
104 p.