Elevated temperature failures in boiler tubes - case studies

  • 1. National Thermal Power Corporation Ltd., New Delhi (India). Research and Development Centre

Description

Metallurgical investigation of boiler tube failures enables identification of failure mechanisms and the underlying cause related to boiler conditions. Some case studies in short term overheating, prolonged overheating and low cycle fatigue failures in boiler tubes are discussed. (author)