Published December 2006
| Version v1
Journal article
Suppression of Zeno effect for distant detectors
- 1. Departamento de Quimica-Fisica, Universidad del Pais Vasco, Apdo. 644, 48080 Bilbao (Spain)
- 2. Departamento de Fisica Basica, Universidad de La Laguna, La Laguna, Tenerife (Spain)
Description
We describe the influence of continuous measurement in a decaying system and the role of the distance from the detector to the initial location of the system. The detector is modeled first by a step absorbing potential. For a close and strong detector, the decay rate of the system is reduced; weaker detectors do not modify the exponential decay rate but suppress the long-time deviations above a coupling threshold. Nevertheless, these perturbing effects of measurement disappear by increasing the distance between the initial state and the detector, as well as by improving the efficiency of the detector
Additional details
Identifiers
- DOI
- 10.1103/PhysRevA.74.062102;
- arXiv
- arXiv:quant-ph/0604005v2;
Publishing Information
- Journal Title
- Physical Review. A
- Journal Volume
- 74
- Journal Issue
- 6
- Journal Page Range
- p. 062102-062102.6
- ISSN
- 1050-2947
- CODEN
- PLRAAN
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 39006239
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- DECAY; DISTANCE; EFFICIENCY; INHIBITION; POTENTIALS; RADIATION DETECTION; RADIATION DETECTORS
- Descriptors DEC
- DETECTION; MEASURING INSTRUMENTS
Optional Information
- Notes
- (c) 2006 The American Physical Society