Description

Highlights: • An integral test of MSLB was conducted in a small-scale test facility, i.e. PUMA which is scaled to generation III + BWR applications. • GDCS as an ECCS provided adequate supply of water to keep RPV coolant level well above TAF. • PCCS kept containment below design pressure during long-term cooling phase. - Abstract: A generation III + Boiling Water Reactor (BWR) which relies on natural circulation has evolved from earlier BWR designs by incorporating passive safety features which require no emergency injection pump and no operator action or Alternating Current (AC) power supply. The generation III + BWR's passive safety systems include the Automatic Depressurization System (ADS), the Suppression Pool (SP), the Standby Liquid Control System (SLCS), the Gravity Driven Cooling System (GDCS), the Isolation Condenser System (ICS), and the Passive Containment Cooling System (PCCS). The ADS is actuated to rapidly depressurize the reactor leading to the GDCS injection. The large amount of water in the SP condenses steam from the reactor. The SLCS provides makeup water to the reactor. The GDCS injects water into the reactor by gravity head and provides cooling to the core. The ICS and the PCCS are used to remove the decay heat from the reactor. The objective of this paper is to analyze the response of passive safety systems under the Loss of Coolant Accident (LOCA). A Main Steam Line Break (MSLB) test has been conducted in the Purdue University Multi-Dimensional Integral Test Assembly (PUMA) which is scaled to represent the generation III + BWR. The main results of PUMA MSLB test were that the reactor coolant level was well above the Top of Active Fuel (TAF) and the reactor containment pressure has remained below the design pressure. In particular, the minimum water level (1.706 m) was 5% higher than the TAF (1.623 m) and the containment maximum pressure (271 kPa) was 35% lower than the safety limit (414 kPa), respectively

Availability note (English)

Available from http://dx.doi.org/10.1016/j.anucene.2013.05.032

Additional details

Identifiers

DOI
10.1016/j.anucene.2013.05.032;
PII
S0306-4549(13)00288-0;

Publishing Information

Journal Title
Annals of Nuclear Energy (Oxford)
Journal Volume
64
Journal Page Range
p. 287-294
ISSN
0306-4549
CODEN
ANENDJ

Optional Information

Copyright
Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.