Published 2006 | Version v1
Journal article

Radiation quality of photons in small and large receptors - A Micro-dosimetric analysis

  • 1. Radiation Protection Bureau, Health Canada, 775 Brookfield Road, Ottawa, Ont. K1A 1C1 (Canada)
  • 2. Radiobiological Inst., Univ. of Munich, Schillerstrasse 42, D-80336 Munich (Germany)

Description

The quality of different photon radiations in small and large receptors is assessed in terms of Micro-dosimetry. Monte Carlo simulations are performed for the electrons released by photons. To represent the case of a small receptor, only electrons released by the non-degraded incident photons are tracked. For a large receptor, all electrons released in the complete degradation process are followed. Dose averaged values, yD, of the lineal energy are derived from the simulated tracks for monoenergetic photons from 10 keV to 2 MeV. In Micro-dosimetry, the dose mean lineal energy is the major parameter of radiation quality. The results demonstrate distinct differences in radiation quality between high-energy gamma rays and conventional X-rays that are present not just in small cell samples but also in large receptors, such as the human body. The values of yD suggest that, for both small and large receptors, conventional X-rays should be about twice as effective as gamma rays from 60Co. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/nci344

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
118
Journal Issue
3
Journal Page Range
p. 238-242
ISSN
0144-8420

Optional Information

Notes
22 refs