Application of cosKERNEL code for NPP shielding calculation

  • 1. Nuclear Power Software Development Center, SPICRI, Beijing (China)

Description

As the basis of shielding design, radiation dose calculation is to ensure that radiation level is lower enough to satisfy a safe dose for relevant personnel. The cosKERNEL is a code to compute the dose rate of nuclear power plant system and equipment based on the point kernel integral method with considering of the various geometries and materials to make sure that the code can meet the requirements. In the paper, four examples are designed and calculated for different situation to prove that the code can be used for shielding calculation analysis of the nuclear power plant. (author)

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Part of:
Proceedings of reactor physics Asia conference 2019 (RPHA19)

Additional details

Publishing Information

Imprint Title
Proceedings of reactor physics Asia conference 2019 (RPHA19)
Imprint Pagination
[321 p.]
Journal Page Range
p. 55-57
Report number
KURNS-EKR--5