Published January 2014 | Version v1
Report Restricted

Reconfirmation of facilities/instruments integrity by cold test of HTTR

  • 1. Japan Atomic Energy Agency, Oarai Research and Development Center, Oarai, Ibaraki (Japan)
  • 2. Japan Atomic Energy Agency, Nuclear Hydrogen and Heat Application Research Center, Oarai, Ibaraki (Japan)

Description

In HTTR, it has passed about two years since the last performance confirmation test. During two years, the integrity of active equipment, leakage efficiency of coolant pressure boundary of piping and vessel and control system performance due to influence of damage and deterioration by earthquake and aging were not confirmed. To confirm them, the cold test by using HTTR was conducted and the system performances such as above mentioned items were evaluated by comparing with the plant data obtained by the past cold test. In the result, no abnormity was found in all the data in the cooling system of HTTR, and it was confirmed that the integrity of facilities and instruments of HTTR was maintained in good condition. (author)

Availability note (English)

Available from JAEA; DOI: https://doi.org/10.11484/jaea-technology-2013-042

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

System files (70.5 kB)

Name Size Download all

Additional details

Publishing Information

Imprint Pagination
54 p.
Report number
JAEA-Technology--2013-042

Optional Information

Notes
8 refs., 27 figs., 10 tabs.