Published November 2017 | Version v1
Journal article

Monte Carlo Simulation of a Segmented Detector for Low-Energy Electron Antineutrinos

  • 1. Atomic Energy Organization of Iran, Nuclear Science and Technology Research Institute (Iran, Islamic Republic of)
  • 2. Amir Kabir University of Technology, Department of Energy Engineering and Physics (Iran, Islamic Republic of)
  • 3. Shahid Beheshti University, Radiation Application Department (Iran, Islamic Republic of)

Description

Detection of low-energy electron antineutrinos is of importance for several purposes, such as ex-vessel reactor monitoring, neutrino oscillation studies, etc. The inverse beta decay (IBD) is the interaction that is responsible for detection mechanism in (organic) plastic scintillation detectors. Here, a detailed study will be presented dealing with the radiation and optical transport simulation of a typical segmented antineutrino detector withMonte Carlo method using MCNPX and FLUKA codes. This study shows different aspects of the detector, benefiting from inherent capabilities of the Monte Carlo simulation codes.

Additional details

Identifiers

Publishing Information

Journal Title
Physics of Atomic Nuclei
Journal Volume
80
Journal Issue
6
Journal Page Range
p. 1119-1125
ISSN
1063-7788
CODEN
PANUEO

Optional Information

Copyright
Copyright (c) 2017 Pleiades Publishing, Ltd.