Assessment of biventricular function using gated blood pool SPECT with QBS software. Comparison with planar radionuclide ventriculography
Creators
- 1. Nippon Medical School, Tokyo (Japan)
Description
Quantitative blood pool SPECT (QBS) in a new application for the quantitative assessment of biventricular function from gated blood pool SPECT (tomographic multi-gated blood pool scintigraphy (TMUGA)). In this study, we compared biventricular function between planar radionuclide ventriculography and TMUGA. The reproducibility of measuring biventricular ejection fraction with QBS was also evaluated. Thirty-five patients with cardiac disease were enrolled. Following intravenous bolus injection of 740 MBq of 99mTc human serum albumin-DTPA, first-pass radionuclide angiography (FP) and 25-gated interval planar multi-gated blood pool scintigraphy (PMUGA) were performed for the measurement of right ventricular ejection fraction (RVEF; %) and left ventricular ejection fraction (LVEF; %), respectively. Subsequently TMUGA data set was acquired with a dual-head gamma camera (16 gated intervals). Then, alternative LVEF and RVEF were measured using TMUGA with QBS. Regional left ventricular wall motion for both PMUGA and TMUGA were assessed with a 4-point scoring system respectively. Automatic biventricular border detection using QBS was feasible in 27 of 35 patients (70.7%). Measurements of TMUGA LEVF and RVEF were well reproducible, with interobserver correlation coefficient of 0.98 and 0.97, respectively. TMUGA LVEF showed excellent correlation with PMUGA LVEF (r=0.98, SEE=3.92%). The agreement of left ventricular (LV) wall motion score between TMUGA and PMUGA was 88.1% (214 of 243 segments), with a kappa value of 0.82. On the other hand, RVEF determined by QBS had a 12.4% average overestimate compared to the same value obtained by FP. Moreover 95% confidential interval of TMUGA RVEF (-28.8 to +4.0%) was wider than that of TMUGA LVEF (-10.7 to +10.7%). TMUGA with QBS analysis provided accurate and reproducible data for global and regional left ventricular function. However, the results of RVEF with TMUGA were not satisfying as a replacement for those with FP and modifying the algorithm were needed to improve accuracy of quantification. (author)
Additional details
Publishing Information
- Journal Title
- Kaku Igaku
- Journal Volume
- 39
- Journal Issue
- 4
- Journal Page Range
- p. 469-476
- ISSN
- 0022-7854
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 34031842
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOLOGICAL FUNCTIONS; COMPARATIVE EVALUATIONS; DTPA; ELECTROCARDIOGRAMS; IMAGE PROCESSING; MYOCARDIAL INFARCTION; MYOCARDIUM; SCINTISCANNING; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY; TECHNETIUM 99; UPTAKE
- Descriptors DEC
- AMINO ACIDS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BODY; CARBOXYLIC ACIDS; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; CHELATING AGENTS; COMPUTERIZED TOMOGRAPHY; COUNTING TECHNIQUES; DIAGNOSTIC TECHNIQUES; DIAGRAMS; DISEASES; DRUGS; EMISSION COMPUTED TOMOGRAPHY; EVALUATION; HEART; HOURS LIVING RADIOISOTOPES; INFORMATION; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MUSCLES; NUCLEI; ODD-EVEN NUCLEI; ORGANIC ACIDS; ORGANIC COMPOUNDS; ORGANS; PROCESSING; RADIOISOTOPE SCANNING; RADIOISOTOPES; RADIOPROTECTIVE SUBSTANCES; RESPONSE MODIFYING FACTORS; TECHNETIUM ISOTOPES; TOMOGRAPHY; YEARS LIVING RADIOISOTOPES