Published November 21, 2010 | Version v1
Journal article

Calibration of the TWIST high-precision drift chambers

Description

A method for the precise measurement of drift times for the high-precision drift chambers used in the TWIST detector is described. It is based on the iterative correction of the space-time relationships by the time residuals of the track fit, resulting in a measurement of the effective drift times. The corrected drift-time maps are parametrised individually for each chamber using spline functions. Biases introduced by the reconstruction itself are taken into account as well, making it necessary to apply the procedure to both data and simulation. The described calibration is shown to improve the reconstruction performance and to extend significantly the physics reach of the experiment.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2010.08.105

Additional details

Identifiers

DOI
10.1016/j.nima.2010.08.105;
arXiv
arXiv:1008.5185v1;
PII
S0168-9002(10)01893-0;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
623
Journal Issue
3
Journal Page Range
p. 954-959
ISSN
0168-9002
CODEN
NIMAER

Optional Information

Copyright
Copyright (c) 2010 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.