Body size-dependent patient effective dose for diagnostic radiography

  • 1. Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan (China)
  • 2. Department of Medical Imaging and Radiological Sciences, Chung Shan Medical University, Taichung, Taiwan (China)
  • 3. Health Physics Division, Institute of Nuclear Energy Research, Loontan, Taiwan (China)

Description

The health-related mean absorbed dose to organs and tissues and the effective dose were usually calculated from the entrance surface dose (ESD) using computational phantoms by the Monte Carlo method. Because these phantoms represented an average adult with simplified organ shape and position within the body, the calculated results were hypothetical doses to the phantom but not to the patient. In order to determine the patient doses, the body size of individual patients should be taken into consideration. In the present work, two approaches were adopted to estimate the radiological thickness of a patient which determined the overlying tissue shielding and photon attenuation in the calculation of organ and effective doses. The first approach involved the determination of this thickness from patient body weight and height. It was found that the body mass index (BMI) was approximately linearly proportional to the body thickness. Therefore, the BMI was used to determine the size-dependent organ and effective doses from patient ESDs measured by the thermoluminescent dosimeters. To verify the applicability of BMI, WinODS software was employed to compute the organ and effective doses using the size- and sex-adjustable anthropomorphic phantom. The second approach involved the estimate of body thickness from the transmission factor, defined as the ratio of exit surface dose to ESD. The transmission factor was measured using polyethylene phantoms of varying thicknesses. Also, a backscatter factor, defined as the ratio of ESDs with and without the presence of patient, was measured using polyethylene phantoms of varying thicknesses

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radmeas.2007.11.028

Additional details

Identifiers

DOI
10.1016/j.radmeas.2007.11.028;
PII
S1350-4487(07)00496-9;

Publishing Information

Journal Title
Radiation Measurements
Journal Volume
43
Journal Issue
2-6
Journal Page Range
p. 1008-1011
ISSN
1350-4487
CODEN
RMEAEP

Conference

Title
15. solid state dosimetry conference
Acronym
SSD15
Dates
8-13 Jul 2007
Place
Delft (Netherlands)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
40008563
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
COMPUTER CODES; MONTE CARLO METHOD; ORGANS; PATIENTS; PHANTOMS; POLYETHYLENES; RADIATION DOSES; SHIELDING; THERMOLUMINESCENT DOSEMETERS; THICKNESS
Descriptors DEC
BODY; CALCULATION METHODS; DIMENSIONS; DOSEMETERS; DOSES; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; MOCKUP; ORGANIC COMPOUNDS; ORGANIC POLYMERS; POLYMERS; POLYOLEFINS; STRUCTURAL MODELS

Optional Information

Copyright
Copyright (c) 2007 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.