Published September 1986 | Version v1
Journal article

Determination of iodine in organic compounds using low-temperature ammoniacal plasma of high-frequency discharge

  • 1. M.V. Lomonosov Moscow State Univ.

Description

This paper presents a method for the determination of iodine in organic compounds, based on the use of a low-temperature ammonial plasma of an electrodeless high frequency discharge. The method was tested on a large number of compounds, and is distinguished by simplicity of operation, rapidity, accuracy and applicability for simultaneous determination of iodine and palladium. The results of the simultaneous determination of iodine and palladium in organic compounds are shown. The relative standard deviation does not exceed 0.011. The duration of each determination is 15-20 min

Additional details

Publishing Information

Journal Title
J. Anal. Chem. USSR (Engl. Transl.)
Journal Volume
41
Journal Issue
3
Series
J. Anal. Chem. USSR (Engl. Transl.).
Journal Page Range
427-430
ISSN
0021-8766
CODEN
JACUA

Optional Information

Notes
Cover-to-cover translation of Zhurnal Analiticheskoj Khimii (USSR).