A CEMS investigation of 57Fe implanted in Al and Cu at low temperature

  • 1. Rijksuniversiteit Groningen (Netherlands). Materials Science Centre
  • 2. Rijksuniversiteit Groningen (Netherlands). Lab. voor Algemene Natuurkunde

Description

A new type of CEM-spectrometer allows in situ measurements on metal foils implanted at low temperatures. It has been used to study defect association and clustering of 57Fe in Al and Cu. For 57FeAl, the substitutional fraction (fs) in samples implanted at 120 K is somewhat smaller than expected for a random impurity distribution but much larger than after room temperature implantation. For 57FeCu, fs for samples implanted at 120 K is less than 0.5 of the value expected for a random distribution and it falls to zero after annealing at 600 K, where more extensive Fe clustering occurs. Vacancy trapping in stage III does not contribute significantly to the observed defect sites. (orig.)

Additional details

Publishing Information

Journal Title
Hyperfine Interactions
Journal Volume
56
Journal Issue
1-4
Series
Hyperfine Interact.
Journal Page Range
1569-1576