Non-invasive assessment of functionally relevant coronary artery stenoses with quantitative CT perfusion: preliminary clinical experiences
Creators
- 1. University of Western Ontario, Medical Biophysics, London, Ontario (Canada)
- 2. Robarts Research Institute, Imaging Research Laboratories, London, Ontario (Canada)
- 3. Lawson Health Research Institute, Imaging Program, London, Ontario (Canada)
- 4. London Health Sciences Centre, Cardiology, London, Ontario (Canada)
- 5. University of Western Ontario, Medical Imaging, London, Ontario (Canada)
- 6. St. Joseph's Health Care, Radiology, London, Ontario (Canada)
- 7. GE Healthcare, CT Engineering, Waukesha, Wisconsin (United States)
Description
We developed a quantitative Dynamic Contrast-Enhanced CT (DCE-CT) technique for measuring Myocardial Perfusion Reserve (MPR) and Volume Reserve (MVR) and studied their relationship with coronary stenosis. Twenty-six patients with Coronary Artery Disease (CAD) were recruited. Degree of stenosis in each coronary artery was classified from catheter-based angiograms as Non-Stenosed (NS, angiographically normal or mildly irregular), Moderately Stenosed (MS, 50-80% reduction in luminal diameter), Severely Stenosed (SS, >80%) and SS with Collaterals (SSC). DCE-CT at rest and after dipyridamole infusion was performed using 64-slice CT. Mid-diastolic heart images were corrected for beam hardening and analyzed using proprietary software to calculate Myocardial Blood Flow (MBF, in mLmin-1100 g-1) and Blood Volume (MBV, in mL100 g-1) parametric maps. MPR and MVR in each coronary territory were calculated by dividing MBF and MBV after pharmacological stress by their respective baseline values. MPR and MVR in MS and SS territories were significantly lower than those of NS territories (p < 0.05 for all). Logistic regression analysis identified MPR MVR as the best predictor of ≥50% coronary lesion than MPR or MVR alone. DCE-CT imaging with quantitative CT perfusion analysis could be useful for detecting coronary stenoses that are functionally significant. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-011-2260-xAdditional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 22
- Journal Issue
- 1
- Journal Page Range
- p. 39-50
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 43028765
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; CARCINOMAS; COMPARATIVE EVALUATIONS; DATA ANALYSIS; DIAGNOSIS; MAGNETIC FIELDS; MAMMARY GLANDS; NMR IMAGING; PATHOLOGICAL CHANGES; SENSITIVITY; SPECIFICITY; SURGERY
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; DISEASES; EVALUATION; GLANDS; MEDICINE; NEOPLASMS; ORGANS