Published April 1991 | Version v1
Report

Control of power dependent safety margins

  • 1. Kernkraftwerk Leibstadt AG, Leibstadt (Switzerland)

Description

The Leibstadt Plant KKL, situated on the river Rhein in Switzerland, is a BWR-6, Mark III, GE-Plant with a BBC turbogenerator set with a net electrical output of 990 MW. In December 1973, the work contract was signed and in December 1984 KKL started the commercial operation. The construction period was influenced by the TMI-incident in 1979. The incident prompted a very tedious design review by the authorities, vendor, and KKL. The PRA-studies were part of the design review. (author). 1 ref., 7 figs, 1 tab

Part of:
Use of probabilistic safety assessment to evaluate nuclear power plant technical specifications

Additional details

Publishing Information

Imprint Title
Use of probabilistic safety assessment to evaluate nuclear power plant technical specifications
Imprint Pagination
293 p.
Journal Page Range
p. 225-233.
Report number
IAEA-TECDOC--599

Conference

Title
Technical committee meeting on the use of probabilistic safety assessment to evaluate nuclear power plant technical specifications.
Dates
18-22 Jun 1990.
Place
Vienna (Austria).

INIS

Country of Publication
International Atomic Energy Agency (IAEA)
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
22081121
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BWR TYPE REACTORS; EVALUATION; NUCLEAR POWER PLANTS; PROBABILISTIC ESTIMATION; SAFETY ANALYSIS; SPECIFICATIONS
Descriptors DEC
ENRICHED URANIUM REACTORS; NUCLEAR FACILITIES; POWER PLANTS; POWER REACTORS; REACTORS; THERMAL POWER PLANTS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS