Published 1998 | Version v1
Journal article

Passive Sampling and Monitoring of Radon and Other Gases (invited paper)

Creators

Description

Passive sampling of radon gas may exploit different phenomena such as the adsorption, solubility, diffusion, and permeability of radon gas in different materials. Sampling methods are described for radon gas which, in principle, apply to all gases. For example, the combination of the polyethylene-based permeation membrane with activated charcoal has been successfully applied for the sampling and monitoring of radon gas and volatile organics often encountered in indoor atmospheres. (author)

Additional details

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
78
Journal Issue
1
Journal Page Range
p. 55-58
ISSN
0144-8420
CODEN
RPDODE