Published April 1995
| Version v1
Miscellaneous
A study on the AP600 passive residual heat removal system
Creators
- 1. Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)
Description
An experimental parametric study of heat exchanger design under nucleate pool boiling conditions has been carried out for application to the passive residual heat removal system of AP600. For various combinations of test parameters, a total of 1,652 experimental data (933 for horizontal tube and 719 for vertical tube) has been obtained. In addition, two empirical correlations for nucleate pool boiling heat transfer, one for vertical tube and the other for horizontal tube, have been derived based on the present experimental data. The agreement between the predictions of the present correlation and experimental data is between +30% and -20%
Additional details
Publishing Information
- Publisher
- KAIF-KNS
- Imprint Place
- Seoul (Korea, Republic of)
- Imprint Title
- Proceedings of the 10th KAIF/KNS Annual Conference
- Imprint Pagination
- 907 p.
- Journal Page Range
- p. 803-812
Conference
- Title
- 10. KAIF/KNS Annual Conference
- Dates
- 6-7 Apr 1995
- Place
- Seoul (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 44064596
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference, Numerical Data, Non-conventional Literature
- Descriptors DEI
- EXPERIMENTAL DATA; HEAT EXCHANGERS; HEAT TRANSFER; NUCLEATE BOILING; POOL BOILING; PWR TYPE REACTORS; RHR SYSTEMS; TUBES; USES
- Descriptors DEC
- BOILING; COOLING SYSTEMS; DATA; ENERGY SYSTEMS; ENERGY TRANSFER; ENRICHED URANIUM REACTORS; INFORMATION; NUMERICAL DATA; PHASE TRANSFORMATIONS; POWER REACTORS; REACTOR COMPONENTS; REACTOR COOLING SYSTEMS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- Imprint:7 refs, 6 figs