Low-dose contrast-enhanced time-resolved angiography with stochastic trajectories with iterative reconstruction (IT-TWIST-MRA) in brain arteriovenous shunt
Creators
- 1. Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, 606-8507, Kyoto (Japan)
- 2. Siemens Healthcare GmbH, Allee am Roethelheimpark 2, 91052, Erlangen (Germany)
- 3. Department of Neurosurgery, Graduate School of Medicine, Kyoto University, 606-8507, Kyoto (Japan)
Description
To assess the feasibility of low-dose contrast-enhanced four-dimensional (4D) time-resolved angiography with stochastic trajectories (TWIST) with iterative reconstruction (hereafter IT-TWIST-MRA) covering the whole brain and to compare IT-TWIST-MRA and TWIST-MRA with reference to digital subtraction angiography (DSA) in the evaluation of arteriovenous shunts (AVS). Institutional Review Board approval was obtained for this observational study, and the requirement for written informed consent was waived. Twenty-nine patients with known AVS underwent TWIST-MRA on a 3-T MRI scanner, using low-dose injection (0.02 mmol/kg) of gadolinium-based contrast agent (GBCA) with each of Fourier and iterative reconstruction between September 2016 and October 2019. Visual evaluation of image quality was conducted for delineation of (a) the normal cerebral arteries and veins and (b) AVS feeder, shunt, and drainer vessels. Region-of-interest evaluation was conducted to evaluate bolus sharpness and baseline signal fluctuation in the signal intensity of the cerebral vessels. We compared the detection of AVS between TWIST-MRA and IT-TWIST-MRA. The paired-samples Wilcoxon test was used to test the differences between TWIST-MRA and IT-TWIST-MRA. Visualization scores for normal vasculature and AVS angioarchitecture were significantly better for images produced using IT-TWIST-MRA than those using TWIST-MRA. Peak signal and the enhancement slope of the time-intensity curve were significantly higher for IT-TWIST-MRA than for TWIST-MRA, except for the superior sagittal sinus (SSS). Baseline intensity fluctuation was significantly lower for IT-TWIST-MRA than for TWIST, except for SSS. IT-TWIST-MRA yields clinically feasible 4D MR-DSA images and delineates AVS even with low-dose GBCA. Iterative reconstruction significantly improves the image quality of TWIST-MRA covering the whole brain. The short temporal footprint and denoising effect of iterative reconstruction enhances the quality of 4D-MRA. IT-TWIST-MRA yields clinically feasible images of AVS with low-dose GBCA.
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-022-08678-7Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology (Internet)
- Journal Volume
- 32
- Journal Issue
- 8
- Journal Page Range
- p. 5392-5401
- ISSN
- 1432-1084
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 53092820
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BLOOD CIRCULATION; BRAIN; BYPASSES; CEREBRAL ARTERIES; COMPARATIVE EVALUATIONS; CONTRAST MEDIA; DATA COMPILATION; FISTULAE; FOUR-DIMENSIONAL CALCULATIONS; IMAGE PROCESSING; IMAGE SCANNERS; ITERATIVE METHODS; MAGNETIC FIELDS; MALFORMATIONS; NMR IMAGING; REVIEWS; STOCHASTIC PROCESSES; TIME RESOLUTION; VEINS
- Descriptors DEC
- ARTERIES; BLOOD VESSELS; BODY; CALCULATION METHODS; CARDIOVASCULAR SYSTEM; CENTRAL NERVOUS SYSTEM; DATA; DATA PROCESSING; DIAGNOSTIC TECHNIQUES; DOCUMENT TYPES; EVALUATION; INFORMATION; NERVOUS SYSTEM; ORGANS; PATHOLOGICAL CHANGES; PROCESSING; RESOLUTION; TIMING PROPERTIES