Published January 1988 | Version v1
Journal article

Steady-state discharge test of coaxial LaB6 cathode

  • 1. Lawrence Berkeley Laboratory, University of California, Berkeley, California 94720

Description

Results of steady-state discharge test of coaxial LaB6 cathodes in a multicusp plasma generator are described. After a single-unit test of a compact, 6.4-mm-diam coaxial LaB6 cathode, a discharge test of two cathodes with one heater power supply was carried out with success. In addition, a new tapered coaxial cathode, which was designed to prevent overheating of LaB6 due to ohmic heating by discharge current, was investigated. During steady-state plasma source operation, a discharge current as high as 180 A was obtained with this tapered cathode

Additional details

Publishing Information

Journal Title
Rev. Sci. Instrum.
Journal Volume
59
Journal Issue
1
Series
Rev. Sci. Instrum.
Journal Page Range
120-124
ISSN
0034-6748
CODEN
RSINA