Development of Automated Ultrasonic Testing System for Partial Joint-Weld of Heat Exchanger's Header to Tube in Power Plant
- 1. Seoul National University of Technology, Seoul (Korea, Republic of)
Description
A power plant's heat exchangers work under poor conditions, such as high temperature, high pressure, corrosion, mechanical stress and vibration. Especially, partial joint-weld of heat exchanger's header to stub-tube is the place where incomplete penetration flaws can easily occur. But, it is hard to evaluate the safety of the structure by conventional nondestructive testing techniques. So it is necessary to test integrity of the weld inside and to develop testing technique and equipment that can detect the flaws at the weld point in order to enhance reliability of the test result. In this study, we developed a suitable automated ultrasonic testing system that can inspect the partial joint-weld of header to stub-tube of power plant. Finally, we showed the efficiency of the automated ultrasonic-testing-system from the application
Additional details
Publishing Information
- Journal Title
- Journal of the Korean Society for Nondestructive Testing
- Journal Volume
- 30
- Journal Issue
- 4
- Series
- 6 refs, 11 figs, 1 tab
- Journal Page Range
- p. 367-372
- ISSN
- 1225-7842
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 42104093
- Subject category
- S42: ENGINEERING; S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Descriptors DEI
- DEFECTS; HEAT EXCHANGERS; NONDESTRUCTIVE TESTING; POWER PLANTS; RELIABILITY; TUBES; ULTRASONIC TESTING
- Descriptors DEC
- ACOUSTIC TESTING; MATERIALS TESTING; NONDESTRUCTIVE TESTING; TESTING