Model SM-1 ballast density gauge

  • 1. Academia Sinica, Beijing, BJ (China). Inst. of Atomic Energy

Description

The ballast density is one of the principal parameters for roadbed operating state. It greatly affects the railroad stability, the accumulation of railroad residual deformation and the amount of work for railroad maintenance. SM-1 ballast density gauge is designed to determine the density of ballast by using the effect of γ-ray passed through the ballast. Its fundamentals, construction, specifications, application and economic profit are described

Availability note (English)

MF available from INIS under the Report Number.

Files

23075461.pdf

Files (372.3 kB)

Name Size Download all
md5:3fa06c13746683836e4ebd4adce0e2e9
372.3 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
12 p.
Report number
CNIC--00394

Optional Information

Secondary number(s)
IAE--0075.