Published 1991 | Version v1
Journal article

Radon concentration measurements in some houses of Lahore

  • 1. Government Science Coll., Lahore (Pakistan). Dept. of Physics
  • 2. Pakistan Inst. of Nuclear Science and Technology, Islamabad (Pakistan). Centre for Nuclear Studies
  • 3. University of the Punjab, Lahore (Pakistan). High Energy Physics Group
  • 4. Pakistan Inst. of Nuclear Science and Technology, Islamabad (Pakistan). Nuclear Engineering Div.

Description

Radon concentration in the bed rooms, kitchens, sitting rooms and TV lounges in some houses in the Lahore has been measured using CN-85 Solid State Nuclear Track Detectors in box type dosimeters. Maximum value of radon concentration is 93 Bq/m/sup 3/ in a bed room whereas the minimum value is 25 Bq/m/ sup 3/ in a TV lounge. The average value of radon concentration in bed rooms, kitchens, sitting rooms and TV lounges varies between 43 Bq/m/sup 3/ and 55 Bq/m/sup 3/. Comparison of radon concentration in the old and new houses has been done and no specific relationship has been observed. (author)

Additional details

Publishing Information

Journal Title
Science International
Journal Volume
3
Journal Issue
2
Series
Sci. Int.
Journal Page Range
117-120
ISSN
1013-5316
CODEN
SINTE