Published July 1, 2014 | Version v1
Journal article

Boron-loaded plastic scintillator with neutron-γ pulse shape discrimination capability

Description

Development of the plastic scintillator with neutron sensitivity from thermal to multi-MeV and pulse shape discrimination (PSD) has been demonstrated. Incorporation of 10B-containing compounds into the plastic scintillator with PSD capability leads to detector improvement in regard to neutron detection efficiency while preserving the discrimination between neutrons and γ-rays. Effects of boron loading on scintillation and pulse shape discrimination properties are discussed. A PSD figure-of-merit value of 1.4±0.03 has been achieved for events in a thermal neutron energy domain, 50–100 keVee, for PSD plastic loaded with 5 wt.% of m-carborane

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2014.03.027

Additional details

Identifiers

DOI
10.1016/j.nima.2014.03.027;
PII
S0168-9002(14)00321-0;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
751
Journal Page Range
p. 62-69
ISSN
0168-9002
CODEN
NIMAER

Optional Information

Copyright
Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.