Sensitivity of experiment on double beta decay of 150Nd search

Description

The possibility of using big area scintillation plates on the basis of polystyrene for creation of the detector of neutrinoless 150Nd double beta decay with sensitivity to half-life period of 1025 years is investigated. The estimations of necessary isotope mass depending on the energy resolution are demonstrated. It is shown that the given sensitivity can be realized by means of such a detector at an isotope mass about 85 kg

Availability note (English)

Available from INIS in electronic form; Also available online: http://wwwinfo.jinr.ru/publish/Preprints/2007/131(P6-2007-131).pdf

Files

39121450.pdf

Files (472.2 kB)

Name Size Download all
md5:c72a44e0bffe3edc876ce0eee32c61a7
472.2 kB Preview Download

System files (40.9 kB)

Name Size Download all

Additional details

Additional titles

Original title (Russian)
Чувствительность эксперимента по поиску двойного бета-распада

Publishing Information

Imprint Pagination
18 p.
Report number
JINR-R--6-2007-131

Optional Information

Contract/Grant/Project number
RSC Kurchatov Institute Grant for fundamental research No.27
Notes
15 refs., 14 figs., 2 tabs.