Published October 1972 | Version v1
Journal article

Digital void velocimeter

  • 1. Hiroshima Inst. of Tech., Itsukaichi (Japan). Faculty of Engineering

Description

The paper describes the principle of measuring digitally the flow velocity of local voids, and discusses the accuracy of this method. It is shown that the spectrum of local void velocities can be determined reliably with digital values. The measurement errors of void velocity ug (m/sec) are within about ±9% in cases when the probes have detector head lengths of 0.8~1.0mm, and head diameters of 0.1 mmφ, when the voids have a flow velocity in the range of 0.2 m/sec≤ug ≤1.2 m/sec and a radius of curvature of void of 2mm≤R≤16mm.

Additional details

Identifiers

Publishing Information

Journal Title
Journal of Nuclear Science and Technology
Journal Volume
9
Journal Issue
10
Series
J. Nucl. Sci. Technol. (Tokyo).
Journal Page Range
613-617
ISSN
1881-1248

INIS

Optional Information

Notes
Updated automatically by Metadata and Full-Text Enrichment Agent