Published 1995 | Version v1
Journal article

Non-intrusive, fast and sensitive ammonia detection by laser photothermal deflection

Description

A recently developed non-intrusive photothermal deflection (PTD) instrument allows sensitive, rapid and quantitative detection of local ammonia concentrations in the air. Ammonia is vibrationally excited by an infrared CO2 laser in an intracavity configuration. A HeNe beam passing over the CO2 laser beam (multipass arrangement) is deflected by the induced refractive index gradient. The detection limit for ammonia in ambient air is 0.5 ppbv with a spatial resolution of a few mm3. The time resolution is 0.1 s (single line) or 15 s (multi line). The system is fully automated and suited for non-stop measuring periods of at least one week. Results were compared to those obtained with a continuous-flow denuder (CFD). (author)

Additional details

Publishing Information

Journal Title
Atmospheric Environment
Journal Volume
29
Journal Issue
10
Journal Page Range
p. 1069-1074
ISSN
0004-6981

Optional Information

Notes
FAO/AGRIS record; ARN: GB19960091398