Published July 1996 | Version v1
Journal article

Optimal concentration of contrast material in chest enhanced CT. A comparative study

  • 1. Osaka Medical Coll., Takatsuki (Japan)

Description

To assess the optimal iodo-concentration for chest enhanced CT, 100 examinations were performed after administering intravenously of iohexol 300 mgI/ml or 240 mgI/ml dose of 100 ml. CT values of aorta were measured in both plain and enhanced CT to evaluate the degree of enhancement. Two radiologists judged the image quality by four degree scores. Artifacts around superior caval vein due to the contrast material were shown in only a few cases. In comparison with enhancement units, iohexol 300 mgI/ml was superior to iohexol 240 mgI/ml. The smaller the patient's weight, the higher the aorta was opacified. On image quality, in small patients weighing less than 60 kg, iohexol 240 mgI/ml was equal to iohexol 300 mgI/ml. Besides, in those weighing more than 60 kg, iohexol 300 mgI/ml was superior to iohexol 240 mgI/ml. (author)

Additional details

Publishing Information

Journal Title
Rinsho Hoshasen
Journal Volume
41
Journal Issue
7
Journal Page Range
p. 741-746.
ISSN
0009-9252
CODEN
RHOSAM

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
28008233
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
AORTA; CAT SCANNING; CHEST; IOHEXOL; NEOPLASMS; VASCULAR DISEASES; VEINS
Descriptors DEC
ARTERIES; BLOOD VESSELS; BODY; BODY AREAS; CARDIOVASCULAR SYSTEM; COMPUTERIZED TOMOGRAPHY; CONTRAST MEDIA; DISEASES; ORGANS; TOMOGRAPHY