Differences in radiation dosage value (CTDIw) and image noise on sequence and spiral engineering in computer tomography face bone (study on modality of scan brand Siemens 6 slice)
- 1. Poltekkes Kemenkes, Semarang (Indonesia)
- 2. Mahasiswa Prodi D-IV Teknik Radiologi (Indonesia)
Description
This Research use parameter of exposure factor are tube current and time (mAs) of CT scan for measuring dose radiation (CTDIw) and image noise with sequence and spiral techniques. The purpose of this research is to know difference of radiation dose (CTDIw) and image noise with sequence and spiral techniques of variation mAs at CT Scan Siemens 6 slice. This research was an experimental study. A five various use of mAs (from 250 mAs up to 290 mAs) and then effect of radiation doses (CTDIw) and image noise due to the techniques being implemented were compared and measured with tested to use paired T-Test to take a conclusion with trust storey level 95 % (ρ value <0,05). That having meaning that there is difference of dose value at sequence and spiral techniques, while test of Wilcoxon at show image noise assess significantly with ρ value equal to 0,000 (ρ value <0,05). It means there are difference of noise image between of sequence and spiral techniques. (author)
Files
51070161.pdf
Files
(342.1 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:8501b375f70a27c52e64ba99a335026c
|
342.1 kB | Preview Download |
Additional details
Additional titles
- Original title (Indonesian)
- Perbedaan indikator nilai dosis radiasi (CTDIw) dan image noise pada teknik sekuens dan spiral pada computed tomography face bone (studi pada modalitas CT scan merk siemens 6 slice)
Publishing Information
- Publisher
- Nuclear Energy Regulatory Agency
- Imprint Place
- Yogyakarta (Indonesia)
- Imprint Title
- Proceedings of the seminar on nuclear safety 2017: Development of nuclear power oversight based on public information and communication technology
- Imprint Pagination
- 389 p.
- Journal Page Range
- p. 190-194
- ISSN
- 1412-3258
- Report number
- INIS-ID--89
Conference
- Title
- The Seminar on Nuclear Safety 2017
- Original Conference Title
- Seminar Keselamatan Nuklir 2017
- Dates
- 1 Aug 2017
- Place
- Yogyakarta (Indonesia)
INIS
- Country of Publication
- Indonesia
- Country of Input or Organization
- Indonesia
- INIS RN
- 51070161
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CAT SCANNING; COMPUTERIZED TOMOGRAPHY; IMAGES; NOISE; RADIATION DOSES; RADIATION PROTECTION; STRUCTURAL CHEMICAL ANALYSIS
- Descriptors DEC
- COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DOSES; TOMOGRAPHY
Optional Information
- Notes
- 26 refs.; 7 tabs.; 3 figs. Imprint:Prosiding seminar keselamatan nuklir 2017: Pengembangan pengawasan ketenaganukliran berbasis teknologi informasi dan komunikasi publik