Published July 1979 | Version v1
Report Restricted

Quick-look report on LOFT nonnuclear experiment L3-0

Description

The preliminary evaluation has been completed of the results from nonnuclear Loss-of-Coolant Experiment (LOCE) L3-0, which was successfully conducted on May 31, 1979, in the Loss-of-Fluid Test (LOFT) facility. LOCE L3-0, the first experiment in the LOFT Small and Intermediate Break Series L3, simulated a small break at the top of the LOFT pressurizer by opening the power operated pressure relief valve. For this experiment, the nuclear core remained installed and in a shutdown condition. The initial conditions and plant configuration were similar to previous nuclear LOCEs performed in experiment Series L2 with the exception of the primary system being isothermal due to the lack of reactor heat input. Selected data, presented in this report, confirm that the objectives of LOCE L3-0 were successfully achieved

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
48 p.
Report number
QLR-L--3-0