Published March 2008 | Version v1
Journal article

Finger doses received during 99mTc injections calculated with GEANT4

  • 1. Chonbuk National University, Jeonju (Korea, Republic of)

Description

To estimate the finger dose absorbed by 99mTc injection, simulations are carried out to calculate the dose equivalent of each finger per second with radioactivity of 370 MBq, based on the GEANT4 simulator. For the 99mTc source of the volume of 0.4mL and the radioactivity of 370 MBq, we obtained the dose equivalent of the right thumb (0.29 μSv · sec-1), the right index finger (1.19 μSv · sec -1), the right middle finger (1.07 μSv · sec-1), the left thumb (4.36 μSv · sec-1), and the left index finger (3.37 μSv · sec -1), respectively. This simulation results may serve as a useful data in the prediction of finger dose absorbed by 99mTc injection

Additional details

Publishing Information

Journal Title
Journal of Radiation Protection
Journal Volume
33
Journal Issue
1
Series
14 refs, 4 figs, 5 tabs
Journal Page Range
p. 41-46
ISSN
0253-4231

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
40108527
Subject category
S63: RADIATION, THERMAL, AND OTHER ENVIRONMENTAL POLLUTANT EFFECTS ON LIVING ORGANISMS AND BIOLOGICAL MATERIALS;
Descriptors DEI
DOSE RATES; FINGERS; PATIENTS; RADIATION DOSES; RADIATION SOURCES; SIMULATION
Descriptors DEC
ARMS; BODY; DOSES; HANDS; LIMBS