Assessment of the performance of the SMERF indoor fire facility with the use of an active calorimeter

  • 1. Sandia National Labs., Albuquerque, NM (United States)
  • 2. GRAM, Inc., Albuquerque, NM (United States)

Description

Tests with a water cooled calorimeter in the SMokE Reduction Facility (SMERF) at Sandia National Laboratories demonstrate that the facility is operational and ready for thermal regulatory testing of containers for radioactive materials. The facility is briefly described, and initial test results summarized

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE95008512; NTIS; US Govt. Printing Office Dep.

Files

26047362.pdf

Files (290.2 kB)

Name Size Download all
md5:3ee2c62d57646f6e6cb534f7d3c1ecd9
290.2 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
3 p.
Report number
SAND--94-2860C

Conference

Title
progress toward understanding.
Acronym
International high-level radioactive waste management conference
Dates
1-5 May 1995.
Place
Las Vegas, NV (United States).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
26047362
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CALORIMETERS; CONTAINERS; DESTRUCTIVE TESTING; HEAT FLUX; PACKAGING; PERFORMANCE; RADIOACTIVE MATERIALS; TEST FACILITIES; TESTING
Descriptors DEC
MATERIALS; MATERIALS TESTING; MEASURING INSTRUMENTS

Optional Information

Contract/Grant/Project number
Contract AC04-94AL85000
Funding organization
USDOE, Washington, DC (United States).
Secondary number(s)
CONF-950570--15.