Engineering aspects of Passavant screening

  • 1. Passavant Corp., Birmingham, AL

Description

The Passavant screen was developed in Europe almost 30 years ago. The Passavant screen is a vertical traveling screen; however, the basic difference between the conventional vertical traveling screen and the Passavant screen is that in the conventional screen water passes through the front screen belt and then the back screen belt, whereas in the Passavant screen the water enters in between the two belts and passes laterally through either of the belts. Thus, theoretically, the screening surface of the Passavant screen is doubled as compared to the same size conventional vertical traveling screen. Various design and operational modifications of the Passavant screen are possible to yield optimum design and performance characteristics which make it amenable to installation at power plants for safe removal of not only fish but also smaller organisms such as fish eggs and larvae. In this paper, details of the screen design and operational characteristics are discussed with notes on how these features can be modified to suit site- and organism-specific requirements

Additional details

Additional titles

Augmented title (English)
Passavant screens--sprocket--driven vertical traveling screen employing semicircular screening baskets

Publishing Information

Imprint Title
Larval exclusion systems for power plant cooling water intakes
Journal Page Range
p. 65-68.
Report number
NUREG/CP--002

Conference

Title
Workshop on larval exclusion systems for power plant cooling water intakes.
Dates
7 - 8 Feb 1978.
Place
San Diego, CA, USA.

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
10449475
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS; S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
AQUATIC ORGANISMS; ENTRAINMENT; FILTRATION; MECHANICAL STRUCTURES; OPERATION; PERFORMANCE TESTING; SCREENS; SPECIFICATIONS; THERMAL POWER PLANTS
Descriptors DEC
POWER PLANTS; SEPARATION PROCESSES; TESTING