A simulation study of high-resolution x-ray computed tomography imaging using irregular sampling with a photon-counting detector
Creators
Description
The purpose of this study was to improve the spatial resolution for the x-ray computed tomography (CT) imaging with a photon-counting detector using an irregular sampling method. The geometric shift-model of detector was proposed to produce the irregular sampling pattern and increase the number of samplings in the radial direction. The conventional micro-x-ray CT system and the novel system with the geometric shift-model of detector were simulated using analytic and Monte Carlo simulations. The projections were reconstructed using filtered back-projection (FBP), algebraic reconstruction technique (ART), and total variation (TV) minimization algorithms, and the reconstructed images were compared in terms of normalized root-mean-square error (NRMSE), full-width at half-maximum (FWHM), and coefficient-of-variation (COV). The results showed that the image quality improved in the novel system with the geometric shift-model of detector, and the NRMSE, FWHM, and COV were lower for the images reconstructed using the TV minimization technique in the novel system with the geometric shift-model of detector. The irregular sampling method produced by the geometric shift-model of detector can improve the spatial resolution and reduce artifacts and noise for reconstructed images obtained from an x-ray CT system with a photon-counting detector. -- Highlights: • We proposed a novel sampling method based on a spiral pattern to improve the spatial resolution. • The novel sampling method increased the number of samplings in the radial direction. • The spatial resolution was improved by the novel sampling method
Availability note (English)
Available from http://dx.doi.org/10.1016/j.nima.2013.05.044Additional details
Identifiers
- DOI
- 10.1016/j.nima.2013.05.044;
- PII
- S0168-9002(13)00632-3;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 726
- Journal Page Range
- p. 175-180
- ISSN
- 0168-9002
- CODEN
- NIMAER
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 45048183
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ALGORITHMS; COMPARATIVE EVALUATIONS; COMPUTERIZED SIMULATION; COMPUTERIZED TOMOGRAPHY; IMAGES; MINIMIZATION; MONTE CARLO METHOD; NOISE; PHOTONS; RADIATION DETECTORS; SAMPLING; SPATIAL RESOLUTION; X RADIATION; X-RAY DETECTION
- Descriptors DEC
- BOSONS; CALCULATION METHODS; DETECTION; DIAGNOSTIC TECHNIQUES; ELECTROMAGNETIC RADIATION; ELEMENTARY PARTICLES; EVALUATION; IONIZING RADIATIONS; MASSLESS PARTICLES; MATHEMATICAL LOGIC; MEASURING INSTRUMENTS; OPTIMIZATION; RADIATION DETECTION; RADIATIONS; RESOLUTION; SIMULATION; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.