Published 1977 | Version v1
Report Restricted

High efficiency mixed species radioiodine air sampling, readout, and dose assessment system

Description

Accidental releases of radioactivity from fission reactors will consist of active vapors or aerosols. Composition of the released plume will depend on the energy of release and fission product volatility. An apparatus is described that can efficiently (95 percent) collect organic or inorganic, particulate or gaseous 131I in the usual concentration range including that below stable atmospheric iodine, and under severe ambient conditions. Response to noble fission gases was reduced to less than 10-4 of an equal iodine airborne activity by heating the collector to approximately 1200C in clean purging air flowing at .14 m3/min for 11 min. Reliable sample size, +-5 percent, was achieved by using a sample air flow regulator. Thyroid dose commitment was mathematically and graphically related to the iodine isotope distribution expected in the environment and to the response of the Civil Defense CDV-700 instrument used to evaluate the sample. Sensitivity of the method allows dose assessment of 1-2 rads to a child's thyroid

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
12 p.
Report number
BNL--22307

Conference

Title
International symposium on the handling of radiation accidents.
Dates
2 Feb - 4 Mar 1977.
Place
Vienna, Austria.

Optional Information

Secondary number(s)
IAEA-SM--125/20; CONF-770220--3.