Published December 2014 | Version v1
Journal article

Intravoxel incoherent motion diffusion imaging of the liver: Optimal b-value subsampling and impact on parameter precision and reproducibility

  • 1. Department of Radiology, Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, One Gustave Levy Place, New York, NY 10029 (United States)
  • 2. Siemens AG, Healthcare Sector, Erlangen (Germany)

Description

Highlights: • We assess the precision and reproducibility of liver IVIM diffusion parameters. • Liver IVIM DWI can be performed with 4 b-values with good parameter precision. • Liver IVIM DWI can be performed with 4 b-values with good parameter reproducibility. - Abstract: Purpose: To increase diffusion sampling efficiency in intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) of the liver by reducing the number of diffusion weightings (b-values). Materials and methods: In this IRB approved HIPAA compliant prospective study, 53 subjects (M/F 38/15, mean age 52 ± 13 y) underwent IVIM DWI at 1.5 T using 16 b-values (0–800 s/mm2), with 14 subjects having repeat exams to assess IVIM parameter reproducibility. A biexponential diffusion model was used to quantify IVIM hepatic parameters (PF: perfusion fraction, D: true diffusion and D*: pseudo diffusion). All possible subsets of the 16 b-values were probed, with number of b values ranging from 4 to 15, and corresponding parameters were quantified for each subset. For each b-value subset, global parameter estimation error was computed against the parameters obtained with all 16 b-values and the subsets providing the lowest error were selected. Interscan estimation error was also evaluated between repeat exams to assess reproducibility of the IVIM technique in the liver. The optimal b-values distribution was selected such that the number of b-values was minimal while keeping parameter estimation error below interscan reproducibility error. Results: As the number of b-values decreased, the estimation error increased for all parameters, reflecting decreased precision of IVIM metrics. Using an optimal set of 4 b-values (0, 15, 150 and 800 s/mm2), the errors were 6.5, 22.8 and 66.1% for D, PF and D* respectively. These values lie within the range of test–retest reproducibility for the corresponding parameters, with errors of 12.0, 32.3 and 193.8% for D, PF and D* respectively. Conclusion: A set of 4 optimized b-values can be used to estimate IVIM parameters in the liver with significantly shorter acquisition time (up to 75%), without substantial degradation of IVIM parameter precision and reproducibility compared to the 16 b-value acquisition used as the reference

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ejrad.2014.09.003

Additional details

Identifiers

DOI
10.1016/j.ejrad.2014.09.003;
PII
S0720-048X(14)00431-8;

Publishing Information

Journal Title
European Journal of Radiology
Journal Volume
83
Journal Issue
12
Journal Page Range
p. 2109-2113
ISSN
0720-048X
CODEN
EJRADR

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
47005422
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ACCURACY; BIOMEDICAL RADIOGRAPHY; COMPARATIVE EVALUATIONS; DIFFUSION; DISTRIBUTION; EFFICIENCY; ERRORS; LIVER; METRICS; OPTIMIZATION; SAMPLING; SIGNAL-TO-NOISE RATIO; WEIGHT
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; DIMENSIONLESS NUMBERS; EVALUATION; GLANDS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY

Optional Information

Copyright
Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.