A laser plasma soft X-ray microscope with Wolter mirrors was developed so that specimens could be set in the atmosphere. Silicon nitride membranes 100 nm thick were used as vacuum-tight windows. Using relatively large windows (0.46 x 0.46 mm2), an adequate working distance for samples, which was approximately 1.2 mm, was assured. The endrance of the vacuum-tight window was measured briefly. Dry biological cells could be observed with resolution better than 100 nm. A preliminary observation of wet biological cells was carried out using a wet environmental sample holder which was composed of only two sheets of silicon nitride membrane. An X-ray micrograph of wet red blood cells from a chicken was obtained without apparent effects of radiation damage. The properties of a vacuum-tight window and a wet sample holder are discussed. (author)

Additional details

Publishing Information

Journal Title
Japanese Journal of Applied Physics. Part 1, Regular Papers, Brief Communications and Review Papers
Journal Volume
45
Journal Issue
2A
Journal Page Range
p. 989-994
ISSN
0021-4922

Optional Information

Notes
20 refs., 14 figs.