Published December 1996 | Version v1
Report Open

Personal radiation monitoring and assessment of doses received by radiation workers (1996)

Description

Since late 1986, all persons monitored by the Australian Radiation Laboratory have been registered on a data base which maintains records of the doses received by each individual wearer. At present, the Service regularly monitors approximately 30,000 persons, which is roughly 90 percent of those monitored in Australia, and maintains dose histories of over 75,000 people. The skin dose for occupationally exposed workers can be measured by using one of the five types of monitor issued by the Service: Thermoluminescent Dosemeter (TLD monitor), Finger TLD 3, Neutron Monitor, Special TLD and Environmental monitor. The technical description of the monitors is provided along with the method for calculating the radiation dose. 5 refs., 7 tabs., 5 figs

Availability note (English)

MF available from INIS under the Report Number.

Files

28056947.pdf

Files (369.2 kB)

Name Size Download all
md5:f3a57476ce20bf5980ece03518288782
369.2 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
35 p.
Report number
ARL/TR--121